How to open the floor heating water distributor valve
The floor heating water distributor is a key component in the floor heating system and is responsible for regulating the flow and temperature of each circuit. Correctly opening the water distributor valve is an important step to ensure the normal operation of floor heating. This article will introduce in detail how to open the floor heating water distributor valve, and attach relevant data to help you operate it better.
1. Basic structure of floor heating water distributor

The floor heating water distributor usually consists of a water inlet valve, a return valve, an exhaust valve and various circuit valves. The following are the main components of a water distributor and their functions:
| Part name | Function |
|---|---|
| water inlet valve | Main valve that controls hot water entering the water distributor |
| Return valve | Main valve that controls the return of hot water to the boiler |
| exhaust valve | Used to remove air from pipes |
| circuit valve | Control the flow of individual floor heating circuits |
2. Steps to open the floor heating water distributor valve
1.Check system status: Before opening the valve, make sure the floor heating system is filled with water and the pressure is normal (usually 1-2bar).
2.Open the water inlet valve and return valve: Turn the handwheels of the water inlet valve and return valve clockwise until they are fully open. At this time, hot water can enter the water distributor and circulate.
3.Open each circuit valve: Open the valves of each circuit one by one as needed. Generally, the valve handle is open when it is parallel to the pipe and closed when it is perpendicular to the pipe.
4.Exhaust operation: Open the exhaust valve until water flows out, then close the exhaust valve. This step ensures that there is no air in the pipes, which could affect the heating effect.
5.check temperature: After waiting for a period of time, check whether the temperature in each room is uniform. If the temperature in a certain room is too low, the valve opening of the corresponding circuit can be appropriately adjusted.
3. Common problems and solutions
| question | Possible reasons | Solution |
|---|---|---|
| A certain room is not hot | The circuit valve is not opened or the opening is insufficient | Check and adjust the valves of the corresponding circuits |
| System pressure drops | Pipe leaks or incomplete exhaust | Check pipes and re-vent |
| Water distributor leaks | Valve seal is not tight | Replace valve or seal |
4. Precautions
1.Avoid frequent opening and closing of valves: Frequent operation of the valve may cause seal wear and affect service life.
2.Regular maintenance: It is recommended to check the status of the water distributor valve before the heating season every year to ensure its normal operation.
3.Professional operation: If you encounter a problem that cannot be solved, it is recommended to contact professional maintenance personnel.
5. Summary
Correctly opening the floor heating water distributor valve is the key to ensuring the efficient operation of the floor heating system. Through the introduction of this article, you should already understand the structure of the water distributor, the steps to open the valve, and the solutions to common problems. I hope this information will help you make better use of your floor heating system and enjoy a comfortable indoor environment.
If you have any other questions, please leave a message in the comment area and we will answer it for you.